24 research outputs found

    A margin-based analysis of the dosimetric impact of motion on step-and-shoot IMRT lung plans

    Get PDF
    PURPOSE: Intrafraction motion during step-and-shoot (SNS) IMRT is known to affect the target dosimetry by a combination of dose blurring and interplay effects. These effects are typically managed by adding a margin around the target. A quantitative analysis was performed, assessing the relationship between target motion, margin size, and target dosimetry with the goal of introducing new margin recipes. METHODS: A computational algorithm was used to calculate 1,174 motion-encoded dose distributions and DVHs within the patient’s CT dataset. Sinusoidal motion tracks were used simulating intrafraction motion for nine lung tumor patients, each with multiple margin sizes. RESULTS: D(95%) decreased by less than 3% when the maximum target displacement beyond the margin experienced motion less than 5 mm in the superior-inferior direction and 15 mm in the anterior-posterior direction. For target displacements greater than this, D(95%) decreased rapidly. CONCLUSIONS: Targets moving in excess of 5 mm outside the margin can cause significant changes to the target. D(95%) decreased by up to 20% with target motion 10 mm outside the margin, with underdosing primarily limited to the target periphery. Multi-fractionated treatments were found to exacerbate target under-coverage. Margins several millimeters smaller than the maximum target displacement provided acceptable motion protection, while also allowing for reduced normal tissue morbidity

    Advancing the Role of Proton Therapy for Spine Metastases Through Diagnostic Scan–Based Planning

    Get PDF
    Purpose: Many patients with metastatic cancer live years beyond diagnosis, and there remains a need to improve the therapeutic ratio of metastasis-directed radiation for these patients. This study aimed to assess a process for delivering cost-effective palliative proton therapy to the spine using diagnostic scan–based planning (DSBP) and prefabricated treatment delivery devices. Materials and Methods: We designed and characterized a reusable proton aperture system that adjusts to multiple lengths for spine treatment. Next, we retrospectively identified 10 patients scan treated with thoracic proton therapy who also had a diagnostic computed tomography within 4 months of simulation. We contoured a T6-T9 target volume on both the diagnostic scans (DS) and simulation scans (SS). Using the aperture system, we generated proton plans on the DS using a posterior–anterior beam with no custom range compensator to treat T6-T9 to 8 Gy × 1. Plans were transferred to the SS to compare coverage and normal tissue doses, followed by robustness analysis. Finally, we compared normal tissue doses and costs between proton and photon plans. Results were compared using the Wilcoxon signed-rank test. Results: Median D95% on the DS plans was 101% (range, 100%–102%) of the prescription dose. Median Dmax was 107% (range, 105%–108%). When transferred to SS, coverage and hot spots remained acceptable for all cases. Heart and esophagus doses did not vary between the DS and SS proton plans (P >.2). Robustness analysis with 5 mm X/Y/Z shifts showed acceptable coverage (D95% > 98%) for all cases. Compared with the proton plans, the mean heart dose was higher for both anterior–posterior/posterior–anterior and volumetric modulated arc therapy plans (P < .01). Cost for proton DSBP was comparable to more commonly used photon regimens. Conclusion: Proton DSBP is technically feasible and robust, with superior sparing of the heart compared with photons. Eliminating simulation and custom devices increases the value of this approach in carefully selected patients

    An organizational approach to comparative corporate governance: Costs, contingencies, and complementarities

    Get PDF
    This paper develops an organizational approach to corporate governance and assesses the effectiveness of corporate governance and implications for policy. Most corporate governance research focuses on a universal link between corporate governance practices (e.g. board structure, shareholder activism) and performance outcomes, but neglects how interdependences between the organization and diverse environments lead to variations in the effectiveness of different governance practices. In contrast to such ‘closed systems’ approaches, we propose a framework based on ‘open systems’ approaches to organizations which examines these organizational interdependencies in terms of the costs, contingencies, and complementarities of different corporate governance practices. These three sets of organizational factors are useful in analyzing the effectiveness of corporate governance in diverse organizational environments. We also explore how costs, contingencies, and complementarities impact effectiveness of different governance aspects through the use of stylized cases and discuss the implications for different approaches to policy such as ‘soft-law’ or ‘hard law’

    A 3D Collision Avoidance Tool for External Beam Radiation Therapy Treatment Planning

    No full text
    Purpose: We are presenting the design and implementation of a 3D‐graphical tool for the detection of potential collisions of various linac components for patient‐specific external treatment planningMethod and Materials: The graphical tool uses the Virtual Reality Modeling Language (VRML) to model the exact geometry of any treatment machine by reading its manufacturer\u27s CAD design files. The robust system is based on VRML and Java programming that allows for accurate simulation of any linac hardware module based on the manufacturer\u27s CAD drawings. Results: The tool predicted eminent collisions between different linac components graphically for a simulated Varian 2100EX for certain gantry and table angles. The collision angles were verified manually on the linac and found to agree with the predicted angles from the tool. Conclusions: We have developed a 3D graphical simulation tool that can be used as a stand alone application to assist in external treatment planning by visually simulating collisions between various linac hardware components. Unlike other anti‐collision methods developed so far in the literature, our tool would be able to model the details of the treatment linac and add‐on devices for patient‐specific setups. Hence, the tool will create patient‐specific realistic collision maps for any external treatment scenario. The tool can be used as a stand‐alone program and it is platform independent

    A Gpu-Based Framework For Modeling Real-Time 3D Lung Tumor Conformal Dosimetry With Subject-Specific Lung Tumor Motion

    No full text
    In this paper, we present a graphics processing unit (GPU)-based simulation framework to calculate the delivered dose to a 3D moving lung tumor and its surrounding normal tissues, which are undergoing subject-specific lung deformations. The GPU-based simulation framework models the motion of the 3D volumetric lung tumor and its surrounding tissues, simulates the dose delivery using the dose extracted from a treatment plan using Pinnacle Treatment Planning System, Phillips, for one of the 3DCTs of the 4DCT and predicts the amount and location of radiation doses deposited inside the lung. The 4DCT lung datasets were registered with each other using a modified optical flow algorithm. The motion of the tumor and the motion of the surrounding tissues were simulated by measuring the changes in lung volume during the radiotherapy treatment using spirometry. The real-time dose delivered to the tumor for each beam is generated by summing the dose delivered to the target volume at each increase in lung volume during the beam delivery time period. The simulation results showed the real-time capability of the framework at 20 discrete tumor motion steps per breath, which is higher than the number of 4DCT steps (approximately 12) reconstructed during multiple breathing cycles. © 2010 Institute of Physics and Engineering in Medicine

    Observations On Real-Time Prostate Gland Motion Using Electromagnetic Tracking

    No full text
    Purpose: To quantify and describe the real-time movement of the prostate gland in a large data set of patients treated with radiotherapy. Methods and Materials: The Calypso four-dimensional localization system was used for target localization in 17 patients, with electromagnetic markers implanted in the prostate of each patient. We analyzed a total of 550 continuous tracking sessions. The fraction of time that the prostate was displaced by \u3e3, \u3e5, \u3e7, and \u3e10 mm was calculated for each session and patient. The frequencies of displacements after initial patient positioning were analyzed over time. Results: Averaged over all patients, the prostate was displaced \u3e3 and \u3e5 mm for 13.6% and 3.3% of the total treatment time, respectively. For individual patients, the corresponding maximal values were 36.2% and 10.9%. For individual fractions, the corresponding maximal values were 98.7% and 98.6%. Displacements \u3e3 mm were observed at 5 min after initial alignment in about one-eighth of the observations, and increased to one-quarter by 10 min. For individual patients, the maximal value of the displacements \u3e3 mm at 5 and 10 min after initial positioning was 43% and 75%, respectively. Conclusion: On average, the prostate was displaced by \u3e3 mm and \u3e5 mm approximately 14% and 3% of the time, respectively. For individual patients, these values were up to three times greater. After the initial positioning, the likelihood of displacement of the prostate gland increased with elapsed time. This highlights the importance of initiating treatment shortly after initially positioning the patient. © 2008 Elsevier Inc. All rights reserved

    Proposal and Evaluation of a Physician-Free, Real-Time On-Table Adaptive Radiotherapy (PF-ROAR) Workflow for the MRIdian MR-Guided LINAC

    No full text
    With the implementation of MR-LINACs, real-time adaptive radiotherapy has become a possibility within the clinic. However, the process of adapting a patient’s plan is time consuming and often requires input from the entire clinical team, which translates to decreased throughput and limited patient access. In this study, the authors propose and simulate a workflow to address these inefficiencies in staffing and patient throughput. Two physicians, three radiation therapists (RTT), and a research fellow each adapted bladder and bowel contours for 20 fractions from 10 representative patient plans. Contouring ability was compared via calculation of a Dice Similarity Index (DSI). The DSI for bladder and bowel based on each potential physician–therapist pair, as well as an inter-physician comparison, exhibited good overlap amongst all comparisons (p = 0.868). Plan quality was compared through calculation of the conformity index (CI), as well as an evaluation of the plan’s dose to a ‘gold standard’ set of structures. Overall, non-physician plans passed 91.2% of the time. Of the eight non-physician plans that failed their clinical evaluation, six also failed their evaluation against the ‘gold standard’. Another two plans that passed their clinical evaluation subsequently failed in their evaluation against the ‘gold standard’. Thus, the PF-ROAR process has a success rate of 97.5%, with 78/80 plans correctly adapted to the gold standard or halted at treatment. These findings suggest that a physician-free workflow can be well tolerated provided RTTs continue to develop knowledge of MR anatomy and careful attention is given to understanding the complexity of the plan prior to treatment
    corecore